 C4998A1-0004
Nominal Frequency Initial Accuracy (Time of Shipment) : Frequency stabilities
Parameter Crystal Frequency stability Condition
OCXO
10.000 MHz 0.10 ppm @ +2.5 VDC EFC
vs. operating temperature range vs. aging per day vs. aging per year vs. short-term (ADEV) vs. supply voltage Frequency tuning
Parameter
SC
< 10 ppb < 1 ppb/day < 50 ppb/yr <1e-11 < 2.0 ppb
-20 to +85C (ref +25C) after 72 hours on power Tau = 1 sec. 5.0 % change
Value
Condition
Electrical frequency control (EFC): Voltage range Pulling slope Linearity RF output
Parameter
0.5 ppm to 1.0 ppm 0 to 5 VDC Positive 20%
Value
Condition
Signal Harmonics Sub-Harmonics Spurious
+3.0 to +7.0 dBm <-25 dBc NA <-80 dBc
50 Ohms 50 Ohms no vibration, minimal EM field and ripple
Supply Voltage
Parameter Value Condition
Supply voltage Power consumption steady state Power consumption during warm up
+ 5.0 V 5% < 2.0 W < 5.0 W
Typical @ 25 C Typical
Corning Frequency Control Custom Datasheet
Revision Date : 2-16-05 SEM
Date Printed: 2005-02-23
1/2
Corning Frequency Control Inc. 100 Watts Street Mount Holly Springs, Pennsylvania 17065, USA Tel 1-717-486-3411 Fax 1-717-486-5920 www.corningfrequency.com Corning Frequency Control GmbH & Co. KG Landstrasse D-74924 Neckarbischofsheim, Germany Tel +49-7268-801-0 Fax +49-07268-801-281 www.corningfrequency.de
C4998A1-0004
Enclosure
Pin 1 2 3 4 5 6 Function Supply Voltage 1 No Connect 2 No Connect Case Ground RF Output EFC
1.500.030 sq 1.00
OCXO
0.58 max
0.030 (0.76) 7 PL.
1 1.00
2
3
6
5
4
0.250
Additional Parameters
Parameter Level Condition
Phase Noise (Static)
Warm-up time
<-102 dBc/Hz <-125 dBc/Hz <-145 dBc/Hz <-153 dBc/Hz <-158 dBc/Hz <-158 dBc/Hz < 5 min
1Hz 10Hz 100Hz 1KHz 10KHz 100kHz To within 0.1 ppm of 1 hour frequency @ 25C
Notes 1 Pin 2 is for Corning internal use: clk. 2 Pin 3 is for Corning internal use: data. 3 Unless otherwise stated all values are valid after warm-up time and refer to typical conditions for supply voltage, frequency control voltage, load, temperature (25C)
Corning Frequency Control Custom Datasheet
Revision Date : 2-16-05 SEM
Date Printed: 2005-02-23
2/2
Corning Frequency Control Inc. 100 Watts Street Mount Holly Springs, Pennsylvania 17065, USA Tel 1-717-486-3411 Fax 1-717-486-5920 www.corningfrequency.com Corning Frequency Control GmbH & Co. KG Landstrasse D-74924 Neckarbischofsheim, Germany Tel +49-7268-801-0 Fax +49-07268-801-281 www.corningfrequency.de


▲Up To Search▲   

 